    Electric Heat Sequencer Control DPST 24 Volt for Q103 24A34-3 1056789 1256504
    Parts Connect Sequencer part number PCQ103.
    24 Volts
    DPST
    1 Timing / 2 Switch
    Off 40-110 Seconds
    On 1-20 Seconds
    PSQ Models are Direct Replacement for Most Fan / Heat Sequencing Functions.
    Terminal Markings are Equivalent to Competitive Types.
    Replacement for Numbers:
    Carrier HN67QC005, ICP (Heil, Comfortmaker, Tempstar, Arcoair) 1056789, HQ1056789,  Diversitech DGS103, Goodman / Amana / Janitrol 1256504 BT1256504, Klixon E017, Mars 33244, 33844, Napco NS103, Supco Q103, White Rodgers 24A34-3. Watsco TDR20, York 525-37322-000.
    COMBINED LOAD RATING TABLE (ALL MODELS)
    30A @ 240 VAC  TOTAL,
    23A Non-Inductive + 7 FLA / 42 LRA Inductive,
    ON Time: Elapsed time to make contacts after heater is energized (min. to max.)
    OFF Time: Elapsed time to break contacts after heater is de-energized (min. to max.)
    M1-M2 and M3-M4 are always first switches to turn ON and last to turn OFF.
    All other switches are random ON and random OFF
    NOTE :
    Underwriters Laboratories requires a fan interlock circuit to insure the blower  remains operating whenever more than one  sequencer is used.
    The fan interlock should  be the M1/ M2 contacts of the second or third sequencer.
    All M1/ M2 contacts are wired to the blower  motor so that any sequencer that is energized  will keep the blower ON.
    Product Details
    Brand
    PartsConnect
    Manufacturer
    PartsConnect
    Product Type
    Sequence Control
    Mpn
    PCQ103
    PartsConnect part number PCQ103
    Electric Heat Sequencer / Motor Fan Blower Control DPST 24 Volt for Q103