Fluke 1750 1420004 Three-Phase Power Quality Logger

$ 3155.85

Availability: 100 in stock
  • Condition: Tested Good
  • Brand: Fluke
  • MPN: 1750
  • Model: Fluke 1750 1420004 Three-Phase Power Quality Logger
  • All returns accepted: Returns Accepted
  • Item must be returned within: 30 Days
  • Refund will be given as: Money Back
  • Return shipping will be paid by: Buyer

    Description

    Fluke 1750 1420004 Three-Phase Power Quality Logger
    Item
    Make: Fluke
    Model: 1750
    Options:
    Item Specifics/Condition
    Tested Good
    Description
    Three-Phase Power Quality Logger
    Record every power quality paramater, every cycle, all the time
    Setting up a power quality analyzer to capture detailed power quality data has never been easier that it is with the Fluke 1750. The only things you need to know are the system voltage, frequency and the power configuration (delta or wye). The analyzer then captures the most important data for up to 30 days without losing the most important details. These power meters automatically record every power quality parameter and event, on every cycle – all the time. Once the data is captured download via Ethernet or directly to 2GB SD card (without the need of any other device). The Fluke 1750 features a wireless front panel for viewing measurements, data and setting up, implemented via a tablet computer using Bluetooth communication.
    Common Applications
    Long-term analysis: Uncover hard-to-find or intermittent issues; monitor critical equipment, capturing power quality events to correlate with equipment malfunction
    Power quality surveys: Quantify power quality throughout a facility, documenting results with professional reports
    Quality of service compliance: Validate incoming power quality at the service entrance
    Equipment Installation/Commissioning: Benchmark: power system prior to install to insure quality of service
    Long-Term Analysis
    – Uncover hard-to-find or intermittent issues.
    Load Studies
    – Verify the available electrical system capacity before adding loads.
    Other useful features:
    Allows you to apply thresholds after data is collected, with Fluke Power Analyze Software–no need to worry about missed information due to incorrect setups
    Captures every measurement, on every channel, every time with cross-channel, and current triggering capture
    Allows you to easily analyze data and generate reports in intuitive PC software with automated EN50160 reporting and compliance
    Automatically creates standard or customized reports with Auto Report and exports reports to almost any format including RTF (Rich Text Format) for editing in Microsoft Word.
    Sets up in minutes with self-identifying current probes and single-lead voltage connections
    Allows you to swap channels internally with the wireless tablet or PC when connections are not correct. No need to reconnect wires
    Measures every parameter voltage and current on three phases, neutral, and ground
    Offers 5 MHz, 8000 Vpk waveform capture to provide a detailed picture of even the shortest events
    Quickly retrieves data with included SD memory card or via the 100BaseT high-speed Ethernet connection.
    Technical Specifications
    Power quality measurement standards
    Conformance
    IEC 61999-1-4 Class 1, IEC 61000-4-30 Class A, S or B depending on measurement function, IEEE519, IEEE1159, IEEE1459 and EN50160
    Clock/calendar
    Leap years, 24-hour clock
    Real-time clock accuracy
    Not more than ±1 s/day
    Internal memory capacity for data
    At least 2 GB
    Maximum recording period
    At least 31 days
    Measurement time control
    Automatic
    Maximum number of events
    Limited only by the size of the internal memory
    Power requirements
    100 to 240 V rms ±10%, 47-63 Hz, 40 W
    Operating time during interruptions (internal UPS operation)
    5 minutes per interruption, 60 minutes total operating time without recharging
    Dimensions
    215 x 310 x 35 mm (8.5 x 12.2 x 3.5 in)
    Mass (weight)
    6.3 kg (14 lb)
    Input
    Measurement types
    One Phase Plus Neutral, One Phase IT No Neutral, One Phase Split Phase, Three Phase Wye, Three Phase Delta, Three Phase IT, Three Phase High Leg, Three Phase Open Leg, 2 Element Delta, 21/2 Element Wye
    Input channels
    Voltage: 4 channels, AC/DC
    Current: 5 channels
    Voltage channels
    Input resistance: 2 MΩ
    Input capacitance: < 20 pF
    Current input characteristics
    2 V rms = full scale, 1 MΩ Input Impedance for ferro CTs, low impedance for Flexi-CTs
    Measuring method
    Simultaneous digital sampling of voltage and current. Digital PLL synchronized sampling, internal frequency reference used during voltage drops.
    Synchronization and sampling
    PLL-synchronization source
    The PLL synchronizes to the A-N voltage for wye power types, and to the A-B voltage for delta power types. All listed power types can be characterized as either wye or delta.
    PLL lock range
    42.5 to 69 Hz
    Sampling frequency
    Voltage and current: 256 samples/cycle Inter-harmonics per IEC 61000-4-7: 2 560 points/10 cycles (50 Hz), 3072 points/12 cycles (60 Hz) Transient Voltage: 5 MHz
    A/D resolution
    Voltage and current: 24 bits
    Transient voltage: 14 bits
    Voltage and current measurements
    Voltage measurement range
    AC voltage: 1000 V rms ±10% over range
    DC voltage: ±1000 V + 10% over range
    Voltage crest factor
    3 or less
    Current measurement range
    Depends on current probe used
    Current crest factor
    4 or less
    RMS voltage
    Measurement type
    True rms calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by IEC 61000-4-30.
    Measurement uncertainty
    AC: ±0.2% reading ±0.1% full scale, above 50 V rms
    DC: ±0.5% reading ±0.2% full scale, above 50 V dc
    RMS current
    Measurement type
    True RMS calculated continuously: every cycle, every 1/2 cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Transient voltage (impulse)
    Measurement type
    Waveshape sampling
    Full scale
    8000 V pk
    Sample resolution
    200 nS
    Measurement uncertainty
    ±5% reading ±20 V (test parameters: 1000 V DC, 1000 V rms, 100 kHz)
    Voltage swell (rms swell)
    Measurement type
    True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data
    Amplitude and duration of swell
    Measurement
    Same as rms voltage
    Voltage dip (rms sag)
    Measurement type
    True RMS (one cycle calculation by overlapping each half cycle - voltage between lines is measured for 3P3W lines and phase voltage is measured for 3P4W lines)
    Displayed data
    Amplitude and duration of dip or interruption
    Measurement
    Same as rms voltage
    Voltage dropout (interruption)
    Measurement type
    Same as voltage dip
    LAN interface
    Connector
    RJ-45
    Speed and type
    10/100 Base-T, auto MDIX
    Communications protocol
    TCP/IP over Ethernet
    Wireless controller interface
    Connection
    wireless (2.4 GHz radio)
    Speed
    up to 700 kbit/second
    Communications protocol
    Bluetooth SPP
    Power Measurements
    Power, battery life
    Measurement type
    True RMS calculated continuously: every cycle, and every 10 or 12 cycles at 50 or 60 Hz respectively, as required by standards
    Frequency
    Measurement range
    42.5 to 69 Hz
    Measurement source
    Same as PLL synchronization source
    Measurement accuracy
    ±10 mHz (10 to 110% of range, with sine wave)
    Power factor
    Measurement range
    0.000 to 1.000
    Measurement accuracy
    ±1 digit from the calculation of each measured value (±3 digits for total)
    Displacement power factor
    Measurement method
    Calculated from the phase difference between voltage fundamental and current fundamental
    Measurement range
    - 1.000 (leading) to + 1.000 (lagging)
    Measurement accuracy
    ±0.5% reading ±2% full scale ±1 digit
    Voltage unbalance and phase sequence
    Measurement method
    Positive sequence voltage divided by negative sequence voltage, per IEC 61000-4-30
    Harmonic voltage and current
    Analysis window
    rectangular
    Analysis order
    1st to 50th order
    Measurement accuracy
    Voltage / Current: 1st to 20th orders: ±0.5% reading ±0.2% full scale, 21st to 50th orders: ±1% reading ±0.3% full scale (current sensor accuracy must be included for current and power)
    Measurement method
    IEC 61000-4-7
    Inter-harmonic voltage and current (intermediate harmonics)
    Analysis window
    rectangular
    Analysis orders
    1.5 to 49.5th order
    Measurement method
    IEC 61000-4-7
    Flicker
    Measurement method
    IEC 61000-4-15
    Plt for 2 hours and Pst for 10 minutes
    Measuring range
    0,1 to 5 (25) depending on voltage level, modulation and frequency
    Environmental Specifications
    Environmental
    Operating environment
    Indoors or in covered area outdoors, up to 2,000 m altitude
    Storage temperature and humidity
    -20°C to 50°C, 80% RH max, non-condensing
    Operating temperature and humidity
    0°C to 40°C, 80% RH max, non-condensing
    Maximum rated working voltage
    Voltage terminals
    1100 V rms
    Voltage durability
    5550 V rms AC for 1 minute, between voltage input terminals, voltage input terminals and current probes, and voltage input terminals and case (50/60 Hz, 1 mA sense current)
    Enclosure protection
    IP30 (per EN 60529)
    Standards
    EMC
    EN 61326-1:1997+A1:1998 Class A
    EN 61000-3-2:1995+A1:1998+A2:1998
    EN 61000-3-3:1995
    Safety
    EN 61010-1 2 nd Edition; 2 000
    Voltage input unit: Contamination Level 2 , Overvoltage Category 1000 V CAT III, 600 V CAT IV (anticipated overvoltage: 8000 V)
    Images
    Term of sale
    Included Items:
    This sale does not include probes, cables, manuals, power cords or any other accessories unless otherwise stated or pictured.