-40%

HT-9600 PM2.5 Detector Particle Monitor Laser Dust Humidity Meter Air Analyzer Z

$ 107.34

Availability: 20 in stock
  • Range: (0-ž1000ug/m3 )
  • Light source: laser diode
  • All returns accepted: Returns Accepted
  • Three-channel dust particle counter: 0.3um 2.5um 1um
  • Storage record: 1000 groups of data
  • MPN: Does Not Apply
  • Concentration unit: piece/L
  • Bundle Listing: No
  • Return shipping will be paid by: Seller
  • Refund will be given as: Money back or exchange (buyer's choice)
  • Detection sensitivity: 1ug
  • Item must be returned within: 30 Days
  • Brand: Unbranded/Generic
  • PM2.5 air quality detection: PM2.5 Pm10
  • Flowrate: 1L/min
  • Condition: New
  • Type: Particle Monitor
  • Country/Region of Manufacture: China

    Description

    Description
    HT-9600 PM2.5 Detector Particle Monitor Laser Dust Humidity Meter Air Analyzer
    Note:The battery is not
    chargeable
    .
    I: Description:
    Handheld dust quick detector is the special detecting instrument used to measure the value of PM2.5 (repairable particles) and PM10 (inhalable particle) in the air. It is a high-tech product developed independently and integrating gas dynamics, digital signal processing and optical-mechanical-electrical integration on the basis of absorbing oversea advanced high sensitivity micro laser sensor technology. The device is characterized by high test precision, stable performance, strong multiple functions and easy and convenient operation and can be used widely for determination of indoor and outdoor public environment and atmospheric environment, PM2.5 air quality detection and PM2.5 dust particle amount.
    II.Specification:
    - PM2.5 air quality detection: PM2.5 Pm10
    - Range: (0-ž1000ug/m3 )
    - Concentration unit: ug/cubic meter (ug/m3)
    - Detection sensitivity: 1ug
    - Measurement error: < ±20%
    - Three-channel dust particle counter: 0.3um 2.5um 10um
    - Flowrate: 1L/min
    - Concentration unit: piece/L
    - Sampling method: pumping
    - Sampling principle: light scattering
    - Light source: laser diode
    - Detection method: manual
    - Automatic power-off function: it will power off automatically if there is no operation within 2 minutes at power-on state.
    - Environmental condition:Application environment: temperature scope: 5℃ï½Âž45℃
    - Storage environment: temperature scope: -20~ž60 C
    - Humidity range: 0-ˆ90%…RH)
    - Sampling time: 50s
    - Resolution ratio of sensor: 1ug/m3
    - Storage record: 1000 groups of data
    - Temperature measurement range: -40~ƒ+125 C Precision ±0.5C
    - Humidity measurement range: 0-100 …RH Precision ±2 …RH
    - Screen size: 2.8″
    - Display screen: 2.8″320*240 LCD color back light
    -
    9V Zinc carbon battery
    ,not chargeable
    Connection of USB port line
    External size: 245*40*85mm
    Weight: 325g (battery included)
    III. Use method
    3.1. Power on
    3.1.1. Take out the product from the package. After the power key is pressed, product LOGO is displayed and it enters the main page and displays the interface of dust particle number/L or PM2.5 air quality ug/m3 (interface may be changed at functional parameters).
    3.2. Power off:
    3.2.1. At power-on state of the instrument, press power key ( )to power off. The instrument will power off automatically if there is no operation within 2 minutes.
    3.3 Description of key function
    3.3.1 RUN key: Press the key once and the instrument’s screen displays the sampling time and begins countdown of 50s. The collected data is displayed once every 10s. For the collected data, the data of last collected is correct reference data.
    3.3.2. When Down key is pressed once, the instrument enters historical record →functional parameter setting in proper order. Data may be checked at the bottom of history page. Press ENTER to confirm the state of certain page for specified check of current page in historical record. At the moment, SHIFT key may be used to select hundred place ←tens place← unit place of current page. Press UP (â–²) key or DOWN (â–¼) key to select 001-999 page of current page.
    At the page of functional parameters, press ENTER to confirm that functional parameters enter change state. At the moment, use SHIFT to select the item to be changed. Press UP (â–²) key or DOWN (â–¼) key to select the function. Press ENTER to confirm completion after selection. Change of parameter function is completed at the moment. Press BACK key to return to previous interface until to the main interface.
    IV. Characteristic of product
    1. Direct reading of dust concentration and digital display;
    2. Innovative electronic cutting technology;
    3. High detecting precision with the principle of light scattering;
    4. Quick response to detection;
    5. Convenient operation and no need for maintenance
    6. Intelligent recognition automatic power off saves power to the greatest extent.
    7. Display of representative color for pollution level;
    V. Display description
    1. Time/date
    2. Area corresponding to representative color for pollution level;
    3. Diameter size of measured particles;
    4. Temperature/humidity
    5. Air quality measurement
    6. Measurement for amount of dust and particles in the air;
    7. Power display
    VI. Product description
    1. LED display screen
    2. Power key
    3. RUN key
    4. ENTER key
    5. SHIFT key
    6. BACK key
    7. UP key
    8. DOWN key
    VII. Standard of indexes
    New standard table for air quality of PM2.5 detection network
    According to new standard table for air quality of PM2.5 detection network, the average standard value is distributed as follows:
    Air quality level
    PM2.5 average and standard value of PM2.5 in 24 hours.
    Excellent
    0 - 35
    Good
    35 - 75
    Slight pollution
    75 - 115
    Moderate pollution
    115-150
    Heavy pollution
    150-250
    Serious pollution
    250 and above
    VIII. Considerations
    1. The device cannot be started if the inlet pipe is covered or blocked.
    2. The product should be placed at a horizontal, dry environment without direct sunlight for storage.
    3. The product should not be placed in an environment with PM2.5 concentration exceeding 999ug/m3. Exposure to air with high concentration of pollution will result in damage of the sensor so that the equipment cannot work normally.
    4. The product should be placed at an area with slow air circulation when it is used for measurement to prevent interfering with the detection result caused by direct blowing of strong air blowing to the inlet pipe.
    5. The product is not provided with waterproof function. Don’t splash water or other liquid onto the device. The service hotline should be dialed at once in case of such condition.
    6. The device should not be used in environment vulnerable to invasion of rain, snow and humid climate. Otherwise, failure may be brought to it.
    7. Don’t dismantle and repair the product without authorization. This may result in failure of the device. Please dial the service hotline if there is any doubt. Our company will not undertake any responsibility for any loss with respect to unauthorized dismantling.
    8. The device should be placed at a stable and safety site to avoid dropping off of the device body.
    Payment Terms
    1.We accept PayPal only.
    2.All major credit cards are accepted through secure payment processor PayPal.
    3.Payment must be received within 7 business days of auction closing.
    4.We ship to your eBay or Paypal address. Please make sure your eBay and Paypal address is correct before you pay.
    Shipping Terms
    1. We ship all the items to your eBay address, please make sure that your eBay address must be correct or send us a message to inform us if you want to change a address before you pay for it.
    2. We ship all our buyers packages with tracking number, and all the items will be sent within 1-2 business days after payment received.
    3. We offer 3 shipping way, Economy Shipping(UBI),25-30 days , Standard Shipping( UBI/ China post/HongKong post), 15-20 days, and Expedited Shipping( EMS,DHL/FeDex/TNT),5-8 days.
    4. For remote regions, we will charge your extra shipping costs. Usually it cost about 35USD-50USD. We will contact you after your payment. Thanks for your understanding.
    Return Terms
    1. If you receive defective item, please kindly notify us within 14 days. We will guide you the returning instruction for replacement or refund.
    2. If you purchased in improper condition, please NOTE that the sipping and handling fee will not be refund, all return shipping fee should paid by the buyer unless item DOA.
    3. We reserve the right to refuse any returns for objective reasons.
    Custom Duties & Taxes
    1. Import duties, taxes, and charges are not included in the item price or postage cost. These charges are the buyer's responsibility.
    2. Avoiding some unnecessary trouble, please check with your country's customs office to inform us what we should declare its value before shipping.
    Feedback
    1. If you are dissatisfied for any reason, please don't be quick to leave us neutral or negative feedback. We work hard to make sure EVERY CUSTOMER 100% SATISFIED and resolve any problem for you and always leave positive feedback to all our customers.
    2. If you are satisfied with the product you received, please kindly leave us a positive feedback and 5 star DSR. If there is any problem of your order, please feel free to contact us firstly, we are responsible and credible seller, will follow it for you asap.